The Open Group Base Specifications Issue 7, 2018 edition
IEEE Std 1003.1-2017 (Revision of IEEE Std 1003.1-2008)
Copyright © 2001-2018 IEEE and The Open Group

NAME

jobs - display status of jobs in the current session

SYNOPSIS

[UP] [Option Start] jobs [-l|-p] [job_id...][Option End]

DESCRIPTION

The jobs utility shall display the status of jobs that were started in the current shell environment; see Shell Execution Environment.

When jobs reports the termination status of a job, the shell shall remove its process ID from the list of those "known in the current shell execution environment''; see Asynchronous Lists.

OPTIONS

The jobs utility shall conform to XBD Utility Syntax Guidelines .

The following options shall be supported:

-l
(The letter ell.) Provide more information about each job listed. This information shall include the job number, current job, process group ID, state, and the command that formed the job.
-p
Display only the process IDs for the process group leaders of the selected jobs.

By default, the jobs utility shall display the status of all stopped jobs, running background jobs and all jobs whose status has changed and have not been reported by the shell.

OPERANDS

The following operand shall be supported:

job_id
Specifies the jobs for which the status is to be displayed. If no job_id is given, the status information for all jobs shall be displayed. The format of job_id is described in XBD Job Control Job ID.

STDIN

Not used.

INPUT FILES

None.

ENVIRONMENT VARIABLES

The following environment variables shall affect the execution of jobs:

LANG
Provide a default value for the internationalization variables that are unset or null. (See XBD Internationalization Variables for the precedence of internationalization variables used to determine the values of locale categories.)
LC_ALL
If set to a non-empty string value, override the values of all the other internationalization variables.
LC_CTYPE
Determine the locale for the interpretation of sequences of bytes of text data as characters (for example, single-byte as opposed to multi-byte characters in arguments).
LC_MESSAGES
Determine the locale that should be used to affect the format and contents of diagnostic messages written to standard error and informative messages written to standard output.
NLSPATH
[XSI] [Option Start] Determine the location of message catalogs for the processing of LC_MESSAGES. [Option End]

ASYNCHRONOUS EVENTS

Default.

STDOUT

If the -p option is specified, the output shall consist of one line for each process ID:

"%d\n", <process ID>

Otherwise, if the -l option is not specified, the output shall be a series of lines of the form:

"[%d] %c %s %s\n", <job-number>, <current>, <state>, <command>

where the fields shall be as follows:

<current>
The character '+' identifies the job that would be used as a default for the fg or bg utilities; this job can also be specified using the job_id %+ or "%%". The character '-' identifies the job that would become the default if the current default job were to exit; this job can also be specified using the job_id %-. For other jobs, this field is a <space>. At most one job can be identified with '+' and at most one job can be identified with '-'. If there is any suspended job, then the current job shall be a suspended job. If there are at least two suspended jobs, then the previous job also shall be a suspended job.
<job-number>
A number that can be used to identify the process group to the wait, fg, bg, and kill utilities. Using these utilities, the job can be identified by prefixing the job number with '%'.
<state>
One of the following strings (in the POSIX locale):
Running
Indicates that the job has not been suspended by a signal and has not exited.
Done
Indicates that the job completed and returned exit status zero.
Done(code)
Indicates that the job completed normally and that it exited with the specified non-zero exit status, code, expressed as a decimal number.
Stopped
Indicates that the job was suspended by the SIGTSTP signal.
Stopped (SIGTSTP)
Indicates that the job was suspended by the SIGTSTP signal.
Stopped (SIGSTOP)
Indicates that the job was suspended by the SIGSTOP signal.
Stopped (SIGTTIN)
Indicates that the job was suspended by the SIGTTIN signal.
Stopped (SIGTTOU)
Indicates that the job was suspended by the SIGTTOU signal.

The implementation may substitute the string Suspended in place of Stopped. If the job was terminated by a signal, the format of <state> is unspecified, but it shall be visibly distinct from all of the other <state> formats shown here and shall indicate the name or description of the signal causing the termination.

<command>
The associated command that was given to the shell.

If the -l option is specified, a field containing the process group ID shall be inserted before the <state> field. Also, more processes in a process group may be output on separate lines, using only the process ID and <command> fields.

STDERR

The standard error shall be used only for diagnostic messages.

OUTPUT FILES

None.

EXTENDED DESCRIPTION

None.

EXIT STATUS

The following exit values shall be returned:

 0
Successful completion.
>0
An error occurred.

CONSEQUENCES OF ERRORS

Default.


The following sections are informative.

APPLICATION USAGE

The -p option is the only portable way to find out the process group of a job because different implementations have different strategies for defining the process group of the job. Usage such as $(jobs -p) provides a way of referring to the process group of the job in an implementation-independent way.

The jobs utility does not work as expected when it is operating in its own utility execution environment because that environment has no applicable jobs to manipulate. See the APPLICATION USAGE section for bg. For this reason, jobs is generally implemented as a shell regular built-in.

EXAMPLES

None.

RATIONALE

Both "%%" and "%+" are used to refer to the current job. Both forms are of equal validity-the "%%" mirroring "$$" and "%+" mirroring the output of jobs. Both forms reflect historical practice of the KornShell and the C shell with job control.

The job control features provided by bg, fg, and jobs are based on the KornShell. The standard developers examined the characteristics of the C shell versions of these utilities and found that differences exist. Despite widespread use of the C shell, the KornShell versions were selected for this volume of POSIX.1-2017 to maintain a degree of uniformity with the rest of the KornShell features selected (such as the very popular command line editing features).

The jobs utility is not dependent on the job control option, as are the seemingly related bg and fg utilities because jobs is useful for examining background jobs, regardless of the condition of job control. When the user has invoked a set +m command and job control has been turned off, jobs can still be used to examine the background jobs associated with that current session. Similarly, kill can then be used to kill background jobs with kill %<background job number>.

The output for terminated jobs is left unspecified to accommodate various historical systems. The following formats have been witnessed:

  1. Killed(signal name)

  2. signal name

  3. signal name(coredump)

  4. signal description- core dumped

Most users should be able to understand these formats, although it means that applications have trouble parsing them.

The calculation of job IDs was not described since this would suggest an implementation, which may impose unnecessary restrictions.

In an early proposal, a -n option was included to "Display the status of jobs that have changed, exited, or stopped since the last status report". It was removed because the shell always writes any changed status of jobs before each prompt.

FUTURE DIRECTIONS

None.

SEE ALSO

Shell Execution Environment, bg, fg, kill, wait

XBD Job Control Job ID, Environment Variables, Utility Syntax Guidelines

CHANGE HISTORY

First released in Issue 4.

Issue 6

This utility is marked as part of the User Portability Utilities option.

The JC shading is removed as job control is mandatory in this version.

Issue 7

SD5-XCU-ERN-97 is applied, updating the SYNOPSIS.

End of informative text.

 

return to top of page

UNIX ® is a registered Trademark of The Open Group.
POSIX ® is a registered Trademark of The IEEE.
Copyright © 2001-2018 IEEE and The Open Group, All Rights Reserved
[ Main Index | XBD | XSH | XCU | XRAT ]